| Title: | Comparison of AI-integrated pathways with human-AI interaction in population mammographic screening for breast cancer |
| Authors: | Frazer, HML Kwok, CF Elliott, MS Chen, YH Wang, C Lippey, JF Hopper, JL Brotchie, P Carneiro, G McCarthy, DJ Al-Qershi, O Fox, SK Hill, B Karthik, R Kunicki, K Li, S Makalic, E Nguyen, TL Ralalage, PB Schmidt, D |
| Issue Year: | 2024 |
| Publisher | NATURE PORTFOLIO |
| Series | NATURE COMMUNICATIONS: |
| Abstract | Artificial intelligence (AI) readers of mammograms compare favourably to individual radiologists in detecting breast cancer. However, AI readers cannot perform at the level of multi-reader systems used by screening programs in countries such as Australia, Sweden, and the UK. Therefore, implementation demands human-AI collaboration. Here, we use a large, high-quality retrospective mammography dataset from Victoria, Australia to conduct detailed simulations of five potential AI-integrated screening pathways, and examine human-AI interaction effects to explore automation bias. Operating an AI reader as a second reader or as a high confidence filter improves current screening outcomes by 1.9-2.5% in sensitivity and up to 0.6% in specificity, achieving 4.6-10.9% reduction in assessments and 48-80.7% reduction in human reads. Automation bias degrades performance in multi-reader settings but improves it for single-readers. This study provides insight into feasible approaches for AI-integrated screening pathways and prospective studies necessary prior to clinical adoption. |
| URI: | https://publications.svi.edu.au/publications/9374 |
| Other Identifiers | 10.1038/s41467-024-51725-8 |
| Publication type | Article |