Title: Comparison of AI-integrated pathways with human-AI interaction in population mammographic screening for breast cancer
Authors: Frazer, HML
Kwok, CF
Elliott, MS
Chen, YH
Wang, C
Lippey, JF
Hopper, JL
Brotchie, P
Carneiro, G
McCarthy, DJ
Al-Qershi, O
Fox, SK
Hill, B
Karthik, R
Kunicki, K
Li, S
Makalic, E
Nguyen, TL
Ralalage, PB
Schmidt, D
Issue Year: 2024
Publisher NATURE PORTFOLIO
Series NATURE COMMUNICATIONS:
Abstract Artificial intelligence (AI) readers of mammograms compare favourably to individual radiologists in detecting breast cancer. However, AI readers cannot perform at the level of multi-reader systems used by screening programs in countries such as Australia, Sweden, and the UK. Therefore, implementation demands human-AI collaboration. Here, we use a large, high-quality retrospective mammography dataset from Victoria, Australia to conduct detailed simulations of five potential AI-integrated screening pathways, and examine human-AI interaction effects to explore automation bias. Operating an AI reader as a second reader or as a high confidence filter improves current screening outcomes by 1.9-2.5% in sensitivity and up to 0.6% in specificity, achieving 4.6-10.9% reduction in assessments and 48-80.7% reduction in human reads. Automation bias degrades performance in multi-reader settings but improves it for single-readers. This study provides insight into feasible approaches for AI-integrated screening pathways and prospective studies necessary prior to clinical adoption.
URI: https://publications.svi.edu.au/publications/9374
Other Identifiers 10.1038/s41467-024-51725-8
Publication type Article